16. HDPE Installation

High-density polyethylene (HDPE) is an extremely versatile material that is utilized for a number of engineering works.

As one of the most versatile plastic materials around, HDPE plastic is used in a wide variety of applications, including plastic bottles, milk jugs, shampoo bottles, bleach bottles, cutting boards, and piping. Known for its outstanding tensile strength and large strength-to-ensity ratio, HDPE plastic has a high-impact resistance and melting point.

Hazard Category Hazards Controls
Injury and Damage 1. Cause by poor communication between worker parties 1. Secure and apply all PTW support documents prior to start the job and kept in one folder

2. Conduct TBM (Tool Box Meeting) and discuss the JSA & work procedure with employees

3. All personnel will wear the appropriate PPE for their specific task

4. Work force has good understanding of task and working to the approved JSA and permit requirement

Injury to personnel 1. Non compliance of safety and HSE procedure during installation of HDPE lining 1. Listen to the instruction of engineer or supervisor in charge and follow the procedure and ensure that the area is free from obstruction

2. Supervisor & foreman must teach the worker how to right positioning of cutting and use gloves for cutting

3. Proper position of manual lifting to prevent back injury

Electrocution, Eye irritation and Skin Burn 1. Lack of safe awareness during electric welding 1. Supervisor must give the instruction of the  worker before the start of the activities

2. Ensure that the grounding cable are installed and perperly grounded

3. Only certified welder having certification for specific job shall be allowed to perform welding job 

4. Work personnel shall wear PPE such as gloves and goggles

5. Work personnel do not away from welding equipment prior to completed work

6. All electric welding equipment will be kept in good repair and used only for the intended purpose

7. Tools must be properly stored when not in use

8. All electrical operated tools shall be double insulated grounded and shall be rated at 220 volts and portable power tools must be equipped with proper function “Dead man switch”

Sips and Trips 1. As poor housekeeping
2. Can cause by inadequate storage materials
1. Good housekeeping a place for everything and all   materials must be keeping right place

2. Materials not obstruction for access

3. Arrange all the materials in neat orderly manner

4. Remove al damage meterial and dispose of properly

저의 경우, 주로 물배관으로 사용되는 배관라인과 Tank 주변 Dike 내부 바닥에 지반침투방지용으로 접했습니다. 

대부분 열을 가해서 접합해야 하며 다루기가 용이하죠!! 전원선 상태 확인 및 다림질과 같은 작업방법의 경우는 화상 상해에 주의해서 작업해야 할 것 입니다.

HDPE도 지중매설된 것들이 많습니다. 터파기할 때 조심하셔야 합니다.

제가 근무한 현장은 물배관을 너무 많이 터트려서 물바다 많이 되었습니다 ^^;;;;

kassy

Recent Posts

[공정안전자료] 동력기계목록

▣ 동력기계목록 별지 제14호 서식   ▣ 기입대상     - 펌프류, 압축기류, FAN류, 교반기류, Crane/Hoist,…

3일 ago

휴대용 가스레인지(부탄캔) 사용

휴대용 가스레인지를 이용한다면 안전사고에 주의하자. 일상에서 흔히 사용되는 휴대용 가스레인지(부탄캔) 폭발사고가 꾸준히 이어지고 있다. 가스…

4일 ago

[공정안전자료] 법 제104조 유해인자 분류기준

산업안전보건법 제7장 유해ㆍ위험물질에 대한 조치 제1절 유해ㆍ위험물질의 분류 및 관리  제104조(유해인자의 분류기준) 고용노동부장관은 고용노동부령으로 정하는 바에 따라…

6일 ago

[공정안전자료] 유해·위험물질목록

[ 유해·위험물질목록, 별지 제13호 서식] _  [ KOSHA Guide 화학물질정보 작성예시 ] _  ▣ 기입대상물질 : 모든…

1주 ago

S마크 안전인증제도

▣ 안전인증제도(S 마크) 개요 S마크는 산업재해예방을 위한 임의인증제도입니다. 안전인증제도는 산업안전보건법 제84조제3항의 규정에 따라 제품의 안전성과…

2주 ago

링거액 발명

링거액은 포도당을 추가한 주사액으로 생리 식염수와 마찬 가지로 체액을 보급하기 위해 사용된다. 링거액은 1831년 개구리의 심장근육 수축력을…

3주 ago